§ 45.2-929. Circuit breakers and switches
A. An automatic circuit breaking device or fuse of the correct type and capacity shall be installed so as to protect each piece of electric equipment and power circuit against excessive overload. Wire or another conducting material shall not be used as a substitute for a properly designed fuse, and every circuit breaking device shall be maintained in safe operating condition.
B. Operating controls, such as switches, starters, or switch buttons, shall be so installed that they are readily accessible and can be operated without danger of contact with moving or live parts.
C. Electric equipment and circuits shall be provided with switches or other controls of safe design, construction, and installation.
D. An insulating mat or other electrically nonconductive material shall be kept in place at each power-control switch and at stationary machinery where a shock hazard exists.
E. Suitable warning signs shall be posted conspicuously at every high-voltage installation.
F. Every power wire or cable shall have adequate current-carrying capacity, be guarded from mechanical injury, and be installed in a permanent manner.
G. Every power circuit shall be labeled to indicate the unit or circuit that it controls.
H. All persons shall stay clear of any electrically powered shovel or other similar heavy equipment during an electrical storm.
I. Every device that is installed on or after July 1, 2005, that provides either short circuit protection or protection against overload shall conform to the minimum requirements for protection of electric circuits and equipment of the National Electrical Code in effect at the time of its installation.
J. Every electric conductor installed on or after July 1, 2005, shall be sufficient in size to meet the minimum current-carrying capacity provided for in the National Electrical Code in effect at the time of its installation.
K. Every trailing cable purchased on or after July 1, 2005, shall meet the minimum requirements for ampacity provided in the standards of the Insulated Cable Engineers Association/National Electrical Manufacturers Association in effect at the time such cable is purchased.
Code 1950, §§ 45-82, 45-82.1, 45-82.3, 45-82.4; 1954, c. 191; 1966, c. 594, §§ 45.1-78, 45.1-80, 45.1-81; 1978, c. 118; 1979, c. 315; 1993, c. 442; 1994, c. 28, § 45.1-161.282; 1999, c. 256; 2005, c. 3; 2021, Sp. Sess. I, c. 387.
Frequently Asked Questions About Virginia § 45.2-929
What does Code of Virginia § 45.2-929 cover?
Section 45.2-929 ("Circuit breakers and switches") is part of the Code of Virginia, the codified statutory law of Virginia. It sets out the legal rule or procedure described in the text above. Statutes are amended regularly, so always verify against the official source.
How do I cite Virginia § 45.2-929?
A common citation format is "Code of Virginia § 45.2-929" (Virginia). Legal writing may require the code abbreviation, section number, and year or edition. Match the style required by your court, professor, or publisher.
Is this the official text of Virginia law?
No. This page is for research and education and may not include the most recent amendments. For official current law, check the Virginia official source linked on this page or consult a licensed Virginia attorney.
How does Virginia § 45.2-929 apply to my situation?
Statutes are interpreted in context, and application depends on your specific facts. Only a licensed attorney in Virginia can advise on how this section applies to you. Contact your state or local bar association for a referral.
Sources & Verification
Not legal advice. Verify against the official source and consult a licensed attorney in Virginia.