§ 52:27d-141.
Except as provided in section 5 of this act, 1 products identified in subsection a. of section 3 of this act 2 shall, at a minimum, meet the following efficiency standards: a. Air purifiers, except industrial air purifiers, shall meet the following requirements
as measured in accordance with the ENERGY STAR Program Requirements Product Specification
for Room Air Cleaners, Version 2.0: (1) Clean air delivery rate for smoke shall be 30 or greater; (2) For models with a clean air delivery rate for smoke less than 100, clean air delivery
rate per watt for smoke shall be greater than or equal to 1.7; (3) For models with a clean air delivery rate for smoke greater than or equal to 100
and less than 150, clean air delivery rate per watt for smoke shall be greater than
or equal to 1.9; (4) For models with a clean air delivery rate for smoke greater than or equal to 150,
clean air delivery rate per watt for smoke shall be greater than or equal to 2.0; (5) For ozone-emitting models, measured ozone shall be less than or equal to 50 parts
per billion (ppb); (6) For models with a Wi-Fi network connection enabled by default when shipped, partial
on mode power shall not exceed two watts; and (7) For models without a Wi-Fi network connection enabled by default when shipped,
partial on mode power shall not exceed one watt. b. A commercial dishwasher shall meet the product specifications of the “Energy Star
Program Requirements for Commercial dishwashers Version 2.0” developed by the United
States Environmental Protection Agency; c. A commercial fryer shall meet the product specifications of the “Energy Star Program
Requirements for Commercial Fryers Version 2.0” developed by the United States Environmental
Protection Agency; d. A commercial hot-food holding cabinet shall meet the product specifications of
the “Energy Star Program Requirements for Commercial Hot Food Holding Cabinets Version
2.0” developed by the United States Environmental Protection Agency; e. A commercial oven shall meet the product specifications of the “Energy Star Program
Requirements for Commercial Oven Version 2.2” developed by the United States Environmental
Protection Agency; f. A commercial steam cooker shall meet the product specifications of the “Energy
Star Program Requirements for Commercial Steam Cookers, Version 1.2” developed by
the United States Environmental Protection Agency; g. A computer or computer monitor shall meet the requirements of the California Code of Regulations, Title 20, Section 1605.3(v) and compliance with those requirements shall be measured in accordance with test
methods prescribed in the California Code of Regulations, Title 20, Section 1604(v) ; h. Electric vehicle service equipment shall meet the product specifications of the
“Energy Star Program Requirements Product Specification for Electric Vehicle Supply
Equipment, Version 1.0” developed by the United States Environmental Protection Agency; i. A faucet, except for a metering faucet, shall meet the standards in this subsection
when tested in accordance with Appendix S to Subpart B of Part 430 of Title 10, Code of Federal Regulations and compliance with those requirements shall be in accordance with the “Uniform Test
Method for Measuring the Water Consumption of Faucets and Showerheads”: (1) A lavatory faucet or a replacement aerator for a lavatory faucet shall not exceed
a maximum flow rate of 1.5 gallons per minute at 60 pounds per square inch; (2) A residential kitchen faucet or replacement aerator for a residential kitchen
faucet shall not exceed a maximum flow rate of 1.8 gallons per minute at 60 pounds
per square inch, with an optional temporary flow rate of 2.2 gallons per minute, provided
the faucet or replacement aerator defaults to a maximum flow rate of 1.8 gallons per
minute at 60 pounds per square inch after each use; and (3) A public lavatory faucet or a replacement aerator for a public lavatory faucet
shall not exceed a maximum flow rate of 0.5 gallons per minute at 60 pounds per square
inch. j. A State-regulated general service lamp shall meet a lamp efficacy of 45 lumens
per watt, when tested in accordance with the applicable federal test procedures for
general service lamps, prescribed in Section 430.23(gg) of Title 10, Code of Federal Regulations ; k. A high color rendering index, cold temperature, or impact-resistant fluorescent
lamp shall meet the minimum efficacy requirements contained in Section 430.32(n)(4) of Title 10, Code of Federal Regulations , as measured in accordance with the “Uniform Test Method for Measuring Average Lamp
Efficacy (LE), Color Rendering Index (CRI), and Correlated Color Temperature (CCT)
of Electric Lamps” in Appendix R to Subpart B of Part 430 of Title 10, Code of Federal Regulations ; l . A portable electric spa shall meet the requirements of the “American National Standard
for Portable Electric Spa Energy Efficiency 14-2019”; m. An in-line residential ventilating fan shall have a fan motor efficacy of no less
than 2.8 cubic feet per minute per watt. All other residential ventilating fans shall have a fan motor efficacy of no less
than 1.4 cubic feet per minute per watt for airflows less than 90 cubic feet per minute
and no less than 2.8 cubic feet per minute per watt for other airflows when tested
in accordance with Home Ventilation Institute Publication 916 “HVI Airflow Test Procedure”; n. A showerhead shall not exceed a maximum flow rate of 2.0 gallons per minute at
80 pounds per square inch when tested in accordance with Appendix S to Subpart B of Part 430 of Title 10, Code of Federal Regulations and compliance with those requirements shall be the “Uniform Test Method for Measuring
the Water Consumption of Faucets and Showerheads”; o . A spray sprinkler body that is not specifically excluded from the scope of the United
States Environmental Protection Agency's WaterSense program “Specification for Spray
Sprinkler Bodies, Version 1.0,” shall include an integral pressure regulator and shall
meet the water efficiency and performance criteria and other requirements of the “Specification
for Spray Sprinkler Bodies, Version 1.0”; p. A urinal or toilet, other than those designed and marketed exclusively for use
at prisons or mental health facilities, shall meet the standards in paragraphs (1)
through (4) of this subsection when tested in accordance with Appendix T to Subpart B of Part 430 of Title 10, Code of Federal Regulations “Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals.”
A toilet shall be required to pass the waste extraction test for toilets in the American
Society of Mechanical Engineers standard A112.19.2, Section 7.9: (1) A wall-mounted urinal, except for a trough-type urinal, shall have a maximum flush
volume of 0.5 gallons per flush; (2) A floor-mounted urinal, except for a trough-type urinal, shall have a maximum
flush volume of 0.5 gallons per flush; (3) A toilet, except for a dual-flush tank-type toilet, shall have a maximum flush
volume of 1.28 gallons per flush; and (4) A dual-flush tank-type toilet shall have a maximum dual-flush effective flush
volume of 1.28 gallons per flush. q. A water cooler shall meet the product specifications of the “Energy Star Program
Requirements Product Specification for Water Coolers, Version 2.0” developed by the
United States Environmental Protection Agency 1
N.J.S.A. § 52:27D-141.22. 2
N.J.S.A. § 52:27D-141.20.
Frequently Asked Questions About New Jersey § 52:27d-141
What does New Jersey Statutes § 52:27d-141 cover?
Section 52:27d-141 is part of the New Jersey Statutes, the codified statutory law of New Jersey. It sets out the legal rule or procedure described in the text above. Statutes are amended regularly, so always verify against the official source.
How do I cite New Jersey § 52:27d-141?
A common citation format is "New Jersey Statutes § 52:27d-141" (New Jersey). Legal writing may require the code abbreviation, section number, and year or edition. Match the style required by your court, professor, or publisher.
Is this the official text of New Jersey law?
No. This page is for research and education and may not include the most recent amendments. For official current law, check the New Jersey official source linked on this page or consult a licensed New Jersey attorney.
How does New Jersey § 52:27d-141 apply to my situation?
Statutes are interpreted in context, and application depends on your specific facts. Only a licensed attorney in New Jersey can advise on how this section applies to you. Contact your state or local bar association for a referral.
Sources & Verification
Not legal advice. Verify against the official source and consult a licensed attorney in New Jersey.