§ RS 51:912.25. Installation standards for used manufactured homes in hurricane zones
When the manufacturer's printed setup requirements are not available for the applicable wind zone, the following guidelines are to be used:
(1) All anchors shall be listed for four thousand seven hundred twenty-five pounds ultimate load.
(2) Longitudinal ties only are required at each end of each unit. The minimum number of ties at a minimum angle of forty-five degrees from vertical is three each for Zone II and four each for Zone III.
(3) All designated tie points on the perimeter side walls shall be equipped with vertical and diagonal ties with stabilizer devices. When tie points are not designated on the side walls, diagonal ties with stabilizer devices shall be spaced a maximum of ten feet for Zone I, eight feet for Zone II, and six feet six inches for Zone III.
(4) Anchors and support piers shall be installed at the center line of each opening over five feet. Support piers shall be installed on each end of the marriage wall and at other locations that may be identified on the marriage wall.
(5) Shear wall interior partition wall which attaches to the side wall and is thirty-six inches or longer shall have vertical ties and support piers installed at each end.
(6) All foundations and piers shall comply with the requirements of this Part.
(7) Multiple section homes shall be mechanically fastened every twenty-four inches at the bottom, end walls, and roof.
(8) A minimum thirty gauge, eight inch wide, galvanized strip shall be centered over the peak and fastened with galvanized roofing nails at two inches on center at both sides of center line.
Acts 1997, No. 970, §1; Acts 2000, 1st Ex. Sess., No. 92, §1; Acts 2001, No. 718, §2; Acts 2007, No. 441, §1; Acts 2008, No. 217, §1; Acts 2017, No. 221, §1.
Source: official Louisiana text · Last verified 2026-08-27
Frequently Asked Questions About Louisiana § RS 51:912.25
What does Louisiana Civil Code § RS 51:912.25 cover?
Section RS 51:912.25 ("Installation standards for used manufactured homes in hurricane zones") is part of the Louisiana Civil Code, the codified statutory law of Louisiana. It sets out the legal rule or procedure described in the text above. Statutes are amended regularly, so always verify against the official source.
How do I cite Louisiana § RS 51:912.25?
A common citation format is "Louisiana Civil Code § RS 51:912.25" (Louisiana). Legal writing may require the code abbreviation, section number, and year or edition. Match the style required by your court, professor, or publisher.
Is this the official text of Louisiana law?
No. This page is for research and education and may not include the most recent amendments. For official current law, check the Louisiana official source linked on this page or consult a licensed Louisiana attorney.
How does Louisiana § RS 51:912.25 apply to my situation?
Statutes are interpreted in context, and application depends on your specific facts. Only a licensed attorney in Louisiana can advise on how this section applies to you. Contact your state or local bar association for a referral.
Sources & Verification
Not legal advice. Verify against the official source and consult a licensed attorney in Louisiana.