Kansas § 2-3305 - Functional anti-pollution devices, requirements. Functional anti-pollution devices shall be used in the chemigation process according to:(a

Full text of Kansas Kansas Statutes Annotated § 2-3305 — Functional anti-pollution devices, requirements. Functional anti-pollution devices shall be used in the chemigation process according to:(a, with citation guidance and answers to common questions.

§ 2-3305. Functional anti-pollution devices, requirements. Functional anti-pollution devices shall be used in the chemigation process according to:(a

2-3305. Functional anti-pollution devices, requirements. Functional anti-pollution devices shall be used in the chemigation process according to:(a) Criteria adopted by the secretary by rules and regulations that, in the secretary's discretion, follow the latest scientific knowledge and technology and that is designed to protect the groundwater and surface water of the state; or(b) the following criteria:(1) Waterline check valve shall be an automatic, quick-closing device capable of preventing the backflow of water chemical mixtures into the source of water supply during times of system failure or equipment shutdown;(2) a chemical injection line check valve shall be used to prevent flow of water from the irrigation system into the chemical supply tank and to prevent gravity flow from the chemical supply tank into the irrigation system;(3) an interlock system shall be used between the power system of the injection unit, the irrigation pumping plant and the pivot, if involved; the interlock shall function so that if the irrigation pump stops, the injection pump will also stop;(4) a functional vacuum relief device shall be used between the waterline check valve and the irrigation pump to reduce the chance of chemical being back-siphoned into the water source; and(5) an automatic low pressure drain shall be used between the waterline valve and the irrigation pump.History: L. 1985, ch. 5, § 5; L. 1989, ch. 7, § 3; L. 1998, ch. 143, § 25; May 7.

Source: official Kansas text · Last verified 2026-08-27

Frequently Asked Questions About Kansas § 2-3305

What does Kansas Statutes Annotated § 2-3305 cover?

Section 2-3305 ("Functional anti-pollution devices, requirements. Functional anti-pollution devices shall be used in the chemigation process according to:(a") is part of the Kansas Statutes Annotated, the codified statutory law of Kansas. It sets out the legal rule or procedure described in the text above. Statutes are amended regularly, so always verify against the official source.

How do I cite Kansas § 2-3305?

A common citation format is "Kansas Statutes Annotated § 2-3305" (Kansas). Legal writing may require the code abbreviation, section number, and year or edition. Match the style required by your court, professor, or publisher.

Is this the official text of Kansas law?

No. This page is for research and education and may not include the most recent amendments. For official current law, check the Kansas official source linked on this page or consult a licensed Kansas attorney.

How does Kansas § 2-3305 apply to my situation?

Statutes are interpreted in context, and application depends on your specific facts. Only a licensed attorney in Kansas can advise on how this section applies to you. Contact your state or local bar association for a referral.

Sources & Verification

Not legal advice. Verify against the official source and consult a licensed attorney in Kansas.